Share
Online message
Download
CIC-D280 Ion Chromatograph
CIC-D280 Ion Chromatograph

    CIC-D280 is the achievements of the National Major Project "The Development and Industrialization of Multi-functional Ion Chromatograph", which can realize the detection of anion, cation, cyanide, iodide and sugar . Only one instrument  with multi-function can meet the detection needs of food safety, biochemical field, environment, water quality, chemical industry, geology and other industries.


Technology Advantage:

  • Cation and anion dual-channel system, both channels operating independently without disturbing each other and cations and anions being detected simultaneously;

  • Built-in low-pressure degassing technology to eliminate bubble interference for  stability;

  • Intelligent cleaning function, through the switching valve to automatically switch the eluent and pure water, to achieve the automatic cleaning of the flow path;

  • Two kinds of detectors (conductivity detector, electrochemical detector) to expand the detection range;

  • Modular configuration can be freely increased or reduced according to the actual needs of users.


Make an inquiry

Pump   

Maximum Pressure:35 MPa(PEEK)

Pressure Display Accuracy:≤0.1MPa

Flow Rate Range:0.001~9.999mL/min


Conductivity Detector    

Cell Volume:≤0.8μL

Detection Range:0~35000μS/cm

Baseline Noise:≤0.05%FS

Baseline Drift:≤3%FS/30min

Temperature Range: Room temperature +5~60℃(41 ~140℉)

Controlling Temperature Accuracy:±0.01℃

Maximum Pressure:10MPa

 

Built-in Eluent Generator    

Eluent Types:KOH/MSA

Eluent Concentration Range:0.1-120mM

Concentration IncrementL:  0.1mM

Flow Rate Range:0.1-5.0mL/min

Pressure:5MPa-20MPa

 

Power Requirements:150W

Dimensions(L*W*H*):350*470*650 (mm)

Net Weight(KG):34

Gross Weight(KG):40


Environmental analysis

Environmental analysis

Environmental analysis

Read more Download
Drinking water analysis

Drinking water analysis

Drinking water analysis

Read more Download

How does the six-way injection valve work

Ion chromatograph connection CIC-D100

Ion Exchange Chromatographic Column: Ion Separation

Development of Ion Chromatography Technology in China -UAE customers visit SHINE

General Mobilization of Ion Chromatography Consumables

Suppressor operation principle

How to dismount one-way valve of pump

How to use pretreatment column C18

Install and use suppressors

How to use pretreatment column Ag/Na /H column

CIC-D100 Ion Chromatograph


CIC-D100 Ion Chromatograph

Conductivity detector


Conductivity detector

Self-regenerating suppressor

SHY-A-6/SHY-C-3
Self-regenerating electrolytic micro-membrane suppressor

Sample injection

VF-02
Electromagnetic six-way sampling valve

Three dimensional automatic injector

SHA-15
Three dimensional automatic injector

High pressure infusion pump (peek)

SH-120A
High pressure infusion pump (peek)

pretreatment column C18 ,RP


SH series pretreatment column

Needle filter


Needle filter

Similar Products

CIC-D100N Ion Chromatograph


CIC-D100N Ion Chromatograph

CIC-D100 Ion Chromatograph


CIC-D100 Ion Chromatograph

CIC-D120 Ion  exchange Chromatograph


CIC-D120 Ion Chromatograph

CIC-D160 Ion Chromatograph


CIC-D160 Ion Chromatograph